External Spray 4 Holes Air Motor

  • External Spray 4 Holes Air Motor Manufacturers, External Spray 4 Holes Air Motor Factory, Supply External Spray 4 Holes Air Motor
  • External Spray 4 Holes Air Motor Manufacturers, External Spray 4 Holes Air Motor Factory, Supply External Spray 4 Holes Air Motor
  • External Spray 4 Holes Air Motor Manufacturers, External Spray 4 Holes Air Motor Factory, Supply External Spray 4 Holes Air Motor
  • video
External Spray 4 Holes Air Motor
  • TEALTH
  • CHINA
  • 3-5 DAYS
  • 10000 PCS

Order code: MEN-02C
Parameters:
Fit with E type air motor, 4 holes connector
Rotation speed :14000-20000RPM
Conform to ISO 13485 standard

Product name: Tealth external irrigation air motor 4 holes

Order Code: MEN-02C

Water spray: External irrigation

Connector: ISO strandard 4 holes, E-type 


Descriptions

E-type Low-speed 1:1, with external cooling system

Air pressure

245392kPa (2.5-4.0 kgf/cm²

Atomized water pressure

200 kPa

Atomized air pressure

200 kPa

Rotation Speed

16 00020 000r/min

Chuck type

Push button/ Latch type

Bur applicable

Φ2.3342.350 mm

Noise

70dB

low speed air motor handpiece

dental low speed handpiece

dental air motor



low speed air motor handpiece


[Handpiece inserting & removal]

Inserting

Insert the E-type handpiece onto the motor and turning all the way until it click to stop.

Removal

Grip both handpiece and motor respectively, pulling and separating.


dental low speed handpiece


[Forward/Reverse Rotation]

1) Forward Rotation: Turn the FWD/REV change ring to“F”.

2) Reverse Rotation: Turn the FWD/REV change ring to “R”.

3) When the FWD/REV change ring is positioned in the middle of “F” and “R”, the drive air is interrupted and the motor does not rotate.

4) When FEW/REV change ring is positioned in F or R, the rotation speed is maximum.

 dental air motor


[Maintenance & Care]

After each treatment, sterilizing handpiece in autoclave according to the following steps:

1. Remove the bur, use brush to clean handpiece, then cleaning outside of handpiece with alcohol solution.

2. Lubricate handpiece.

3. Package into autoclaving pouch.

4. Autoclave the handpiece for 12 min at 135℃.

5. Dental handpieces cannot be soaked in a disinfectant with acidic liquid. it will seriously damage the bearings and handpiece internal components

6. Do not use an ultrasonic cleaner to clean the dental handpiece.

7. It is not recommended to repair the dental handpiece by little experience person. For repairing, please return to the factory or send to the designated after-sales service maintenance office.



Assembling Lines
Assembling Lines
Teating Machines
Teating Machines