Internal Spray 2 Holes Air Motor dental handpiece

  • Internal Spray 2 Holes Air Motor dental handpiece Manufacturers, Internal Spray 2 Holes Air Motor dental handpiece Factory, Supply Internal Spray 2 Holes Air Motor dental handpiece
  • Internal Spray 2 Holes Air Motor dental handpiece Manufacturers, Internal Spray 2 Holes Air Motor dental handpiece Factory, Supply Internal Spray 2 Holes Air Motor dental handpiece
  • Internal Spray 2 Holes Air Motor dental handpiece Manufacturers, Internal Spray 2 Holes Air Motor dental handpiece Factory, Supply Internal Spray 2 Holes Air Motor dental handpiece
  • Internal Spray 2 Holes Air Motor dental handpiece Manufacturers, Internal Spray 2 Holes Air Motor dental handpiece Factory, Supply Internal Spray 2 Holes Air Motor dental handpiece
  • Internal Spray 2 Holes Air Motor dental handpiece Manufacturers, Internal Spray 2 Holes Air Motor dental handpiece Factory, Supply Internal Spray 2 Holes Air Motor dental handpiece
  • video
Internal Spray 2 Holes Air Motor dental handpiece
  • TEALTH
  • CHINA
  • 3-5 DAYS
  • 10000 PCS

Order code: BIN-01C
Parameter:
Air/ water tube , internal water system
Match up E type motor , 2 hole conneciton
Rotation speed :14000-20000RPM
Conform to ISO 13485 standard

Product name: Tealth internal irrigation air motor 2 holes

Order Code: BIN-01C

Water spray: Internal irrigation

Connector: ISO strandard 2 holes, E-type 

Separated air tube & water pipe, perfect cooling system.


Descriptions

E-type Low-speed 1: 1, internal cooling system

Specifications

1020-M4/1020-B2

Air pressure

392kPa

Atomized water pressure

200 kPa

Atomized air pressure

200 kPa

Chuck type

Push button/Manual Operation

Bur applicable

Φ2.334~2.350 mm

Noise

≤70dB

air motor dental handpiece

dental handpiece

low speed handpiece



air motor dental handpiece


[Handpiece inserting & removal]

Inserting

Insert the E-type handpiece onto the motor and turning all the way until it click to stop.

Removal

Grip both handpiece and motor respectively, pulling and separating.


dental handpiece


[Forward/Reverse Rotation]

1) Forward Rotation: Turn the FWD/REV change ring to“F”.

2) Reverse Rotation: Turn the FWD/REV change ring to “R”.

3) When the FWD/REV change ring is positioned in the middle of “F” and “R”, the drive air is interrupted and the motor does not rotate.

4) When FEW/REV change ring is positioned in F or R, the rotation speed is maximum.

 low speed handpiece


[Maintenance & Care]

After each treatment, sterilizing handpiece in autoclave according to the following steps:

1. Remove the bur, use brush to clean handpiece, then cleaning outside of handpiece with alcohol solution.

2. Lubricate handpiece.

3. Package into autoclaving pouch.

4. Autoclave the handpiece for 12 min at 135℃.

5. Dental handpieces cannot be soaked in a disinfectant with acidic liquid. it will seriously damage the bearings and handpiece internal components

6. Do not use an ultrasonic cleaner to clean the dental handpiece.

7. It is not recommended to repair the dental handpiece by little experience person. For repairing, please return to the factory or send to the designated after-sales service maintenance office.



Parts Factory
Parts Factory
Assembling Lines
Assembling Lines
Get the latest price? We'll respond as soon as possible(within 12 hours)

Privacy policy

close left right